EVOLUTION - 88% HIGH EFFICIENCY WATER HEATERS - ON/OFF AND MODULATING, INDOOR


EVAW Indoor Water Heater*

Literature

Specifications

I&O Manual

Modulating with RWF40

Submittals

Revit Drawings

Wiring Diagrams

On/Off

Submittals

Revit Drawings

Wiring Diagrams

 

 * If you were looking for the EVSW Indoor Water Heater using the Thermal Solutions Boiler Control, please click here
 * If you were looking for the EVOW Outdoor Water Heater, please click here

 

HIGHLIGHTS

• Efficiencies up to 88%

• Ultra-low NOx levels below 9 ppm; meets or exceeds the most stringent emission requirements in the United States

• CO less than 50 ppm

• Quiet operation (<50 dBA)

• Maintenance-free ceramic radiant burner design

• Gasketless header design; minimizes the potential for leaks

• High quality copper-finned tubes extruded from solid copper piping; wall thickness is the best in the industry at .072"

• Copper tubes are individually accessible for cleaning or inspection and replaceable to eliminate the need for whole heat exhanger replacement

• Standard UL/FM/CSD-1 gas train; optional (2) Motorized GasValves with or without Proof of Closure and a N.O. Vent Valve

• Single-point electrical hook-up for all voltage options (120-208-230/1/60 and 208-230-480/3/60)

• Multiple relief valve settings (30, 50, 60, 75, 100, 125 and 150 psig)

• Gas pressures range from 4" wc up to 5 psig

• Infinitely proportional firing (Modulating models only)

• Electric spark-to-pilot-ignition system

• Aluminum non-sparking fan assembly

• Bronze headers

• VFD air control; no dampers or linkages (Modulating models only)

• Inlet air filter 99% efficient to 1 micron

• Non-propretary parts

• Jacket design lends itself to complete access to all components for easy serviceability

• Quick-connect compact package; maximum footprint is 6 sq/ft

• Sealed combustion or room air ready

• Reduced stack sizes — multiple venting options: sealed,direct and conventional

• Factory fire-test on every unit

PACKAGED SYSTEMS

• ASME Section VIII tanks certified at 150 PSIG MAWP

• Vertical or Horizontal tank design

• Epoxy, glass or cement tank lining available

• Jacket and/or insulation available

• Direct package systems include our water heater with an all bronze pump, tank, and controls

• Indirect package systems include our boiler with a cast iron pump, heat transfer tube bundle installed in the tank and controls

• Sole source responsibility - Equipment is prepiped, wiredand mounted on bolted skids (unions in piping) for ease of installation